The complete PreciFill™ Pump system (including all optional items) consists
of:
a) PreciFill™ Pump. Contains all controls and
moving parts in a light, convenient, easily cleaned plastic assembly.
b) AC power source. CSA approved and detachable
from the PreciFill. Plugs into the back of the PreciFill.
c)
Block
Holder – Oral Dose. Holds the adaptor for oral syringes. Mounts on the PreciFill.
d) Block Holder – IV.
Holds the adaptor for IV syringes (sold separately).
e) Master syringe. Standard hospital supply BD-style
disposable syringe with female-luer connection (sold separately).
f)
PreciFill
tubing set. Disposable
tubing set that connects the source container (bottle, bag, etc) to the PreciFill
system (sold separately).
g) adaptor. Standard hospital supply adaptor with a
male-luer connection (sold separately).
h) PreciFill footpedal. Pedal to start and stop the
filling process. An alternative to manual and automated methods (sold
separately).
i)
Anchor. Attaches to the Source end of
the tubing set and weighs it down to the bottom of the source container.
j)
Target. The end receptacle of the filling
process. May be anything that can be attached to the tubing set either directly
or via an adaptor. Common targets are oral-dose syringes and IV bags. (sold
separately)
The power supply furnished with the PreciFill™ Pump is a CSA or ULc certified
unit, which can be plugged into any AC source 100v to 240v. It is rated at 1.4A
input current and delivers 3.35 A at 20V DC.
The power supply should be plugged into the PreciFill
before the being plugged into a power outlet.
The Block holder mounts in the Block holder area of the PreciFillTM
Pump and holds the Delivery end of the tubing set. It has grooves for mounting
to the PreciFill, a locking screw, grooves for threading the tubing set and
adaptor, and a thumbscrew for locking the tubing set in place.
There are two variations of the Block holder, each for
use depending on the type of target
container being filled.
1) Oral-dose Syringes. This block holds the filling circuit so that syringes are filled in a vertical, “tip down” position. It mates with the standard disposable oral syringe adaptor.
2) IV Syringes & Bags. This block mates with the standard disposable intravenous syringe adaptor. It can also accommodate syringes with needles by presenting the circuit so that syringes are held in a horizontal position, “pointing to the right”.
The Tubing set connects the source container to the Master syringe and the target. Only tubing sets specifically designed for use with the PreciFillTM Pump are recommended for use. There are two models available to suit the source product and production.
Tubing sets are individually packaged, terminally
sterilized and are sold in boxes of 25.
|
Tubing
Set |
Characteristics |
Product /
Production Requirements |
|
Low Flow Set (BX-3052) |
Small bore tubing, Female-luer connection to
source |
IV liquids/ Suspension / volumes under 5ml |
|
High Flow Set (BX-3051) |
Large bore tubing, open connection to source |
Oral liquids / volumes over 5ml |
|
The anchor has two openings designed to fit either
tubing set. It prevents the pump from aspirating air by weighing the tubing
down in the Source container. |
The Precifill footpedal can be used to start and stop filling cycles.
|
An adaptor to connect an
oral slip syringe target to the PreciFill pump system. |
|
A 12” adaptor to allow the PreciFill pump system to
fill open containers. |
A 7”
luer lock to luer lock adaptor to connect the PreciFill pump system to luer
lock targets.
A plunger-replacement for the PreciFill master syringe to allow filling of syringe-deteriorating
liquids such as docusate sodium.
![]() |
Copyright © 2015 BioExpert International Inc. All rights reserved. Precifill™ is a product and trademark of BioExpert International Inc. Tel.: +1 514-907-9469 Fax.: +1 514-336-7111 info@bioexpert.ca |
Language: |